EKC Series – chennai india, EKC Series – chennai, EKC Series – , general ac EKC Series – , EKC Series – , ERC Series – chennai tamil . RI8NB R INSTRUCTIONS. EKC D (B). R Type: Pt Instructions RI8NB © Danfoss 05/ EKC D. EKC B Controller with two relay outputs, extra temperature sensor and digital EN and EN , A2 Weight = g Danfoss can accept no.

Author: Totaur Nihn
Country: Romania
Language: English (Spanish)
Genre: Music
Published (Last): 25 May 2017
Pages: 434
PDF File Size: 7.54 Mb
ePub File Size: 2.22 Mb
ISBN: 879-5-13348-998-5
Downloads: 67865
Price: Free* [*Free Regsitration Required]
Uploader: Faukazahn

Copying still going on The information can be found in o65 or o66 a couple of seconds after copying has been started. EKC C Controller with two relay outputs, extra temperature sensor and digital input.

This also applies to products already on order provided that such alternations can be made without subsequential changes being necessary in specifications already agreed. If wkc time is passed, a defrost will be started. Correction of signal from Sair Compensation possibility through long sensor cable. Defrost method Here you set whether defrost is to be accomplished with electricity, natural or “non”.

Controller for temperature control – EKC Manual |

If the defrost sensor registers a higher temperature than the one set here, the fans will be stopped. The alarm disappears again when the temperature has dropped 10 degrees. This timer function can be used as a simple way of starting defrosts, but it will always act as safety defrost if one of the subsequent defrost starts is not received.

Operating status The controller goes through some regulating situations where it is just waiting for the next point of the regulation. The relay is cut out during normal operation and cuts in in alarm situations and when the controller is dead de-energised Refrigeration 2. The display shows the actual room temperature, but by activating the keys the display changes To the set or the actual temperature of the defrost sensor.

Defrost can be accomplished with electricity or natural defrost. When there is an alarm all the light-emitting diodes LED will flash on the controller front panel Alarm delay short alarm delay If one of the two limit values is exceeded, a timer function will commence.

  LG300G MANUAL PDF

HVAC Danfoss Electronic Temperature Controller type Danfoss EKC 102D 084B8506 for Freezer

It may however also be used as product sensor or condenser sensor. Sign me up to an availability notification.

The controller is used for temperature control refrigeration appliances and cold room. Digital input Can be used for the following functions: Between two defrosts the S5 temperature will become lower the more the ddanfoss ices up the compressor operates for a longer time and pulls the S5 temperature further down. RA Box type air outlet from side Medium and high temperature scroll air-cooled condensing unit scroll ZB series.

When the value is passed, a defrost will start. Find the parameter code you want to change and push the middle buttons until value for the parameter is shown. The controller will register when the DI input is activated. Enter contact details and we will notify you, when the product is available. Temperature control, defrost control, fan control, panel embedded installation of small refrigeration equipment and cold storage The controller is simple to install, 16A high current relay output can not directly load intermediate relays, such as compressors, defrosting without parts, danofss.

The set value can be locked or limited to a range with the settings in r02 and r Defrost on demand danfosz S5 temperature The controller will follow the effectivity of the evaporator, and via internal calculations and measurements of the S5 temperature it will be able to start a defrost when the variation of the S5 temperature becomes larger than required.

EKC for panel mounting and EKC for DIN-rail mounting have been specially developed for control duties in refrigeration plant so that operation, setting and dqnfoss are optimised and simplified as much as possible. Ask for this product: Activation can also take place via input DI defined in o There is no temperature monitoring during case cleaning.

ON-time in minutes Min. Providing personal data is voluntary, but necessary for providing a reply. The interval time is not active when set to 0. When the input is short-circuited, there will be regulation for night operation. Activation of reference displacement When the function is changed to ON the thermostat differential will be increased by the value in r R22 Medium and high temperature scroll air-cooled condensing elc Open air outlet from side scroll ZB series.

  DESCARGAR LA TEOGONIA DE HESIODO COMPLETA PDF

And for how long it at least has to be stopped. However the view of —d- will be discontinued if: A measurement of the defrost temperature can be obtained directly through the use of an S5 sensor. The function delays the interval time d03 by the set number of minutes, but it only does it once, and this at the very first defrost taking place when voltage is connected to the controller.

Temperature signal 2 can be used for defrost stop based on temperature or for product sensor. Activation can take place via r39 or input DI Alarm The controller can give alarm in different situations. Push the upper or the lower button and select the new value 3.

In central systems the function must be cut out. A-model for simple regulation B-model where an alarm function and possibly also a digital input will be required C-model where the defrost temperature also enjoys top priority D-model with fan function, change-over between temperature reference and case cleaning function All these four controllers are without data communication.

The time when water drips off the evaporator. Copy from the programming key This function downloads a set of settings earlier saved in the controller.

Access code 2 Access to adjustments There is access to adjustments of values, but not to configuration settings. Easy returns wizard All returns processed by our shop are managed in a easy-to-use returns wizard which gives you the ability to send a return parcel. Here you define which: After two seconds you can move into the menu again and check whether the copying was satisfactory.

The relay cuts in when lower temperatures are required. Refrigeration stopped, fan continues or stops as defined in F A-alarms will not become visible until the set time delay has expired.